LAL Chromogenic Endpoint assay For Endotoxin Detection  

データシート SDS 掲載ホームページ
感度 0.04 EU/ml
測定範囲 0.04-10.0 EU/ml
使用目的 エンドトキシンを特異的に検出・測定する高感度なキットです。
様々な生体液(血清など)、装置、エアフィルター、組織培養培地などに含まれる細菌内毒素を、in vitro で定量することができます。
構成内容 ●スタンダード
●LAL試薬
●エンドトキシンフリー水(EFW)
●停止液
●12 マイクロタイターストリップ
参考文献 1. Kuula, H et al; Local and Systemic Responses in Matrix Metalloproteinase 8-Deficient Mice during Porphyromonas gingivalis-Induced Periodontitis. Infection and Immunity 2009, 77: 850
2. Nymark, M et al; Serum Lipopolysaccharide Activity Is Associated With the Progression of Kidney Disease in Finnish Patients With Type 1 Diabetes. Diabetes Care 2009, volume 32 9: 1689
3. Demberg, T et al; Strong viremia control in vaccinated macaques does not prevent gradual Th17 cell loss from central memory. Vaccine 2011, 29: 6017
4. Kalambokis, G et al; Circulating endotoxin and interleukin-6 levels are associated with Doppler-evaluated pulmonary vascular resistance in cirrhotic patients. Hepatol Int 2012
使用文献 Whalen KA et al., In vitro allergen challenge of peripheral blood induces differential gene expression in mononuclear cells of asthmatic patients: inhibition of cytosolic phospholipase A2α overcomes the asthma‐associated response. Clin Exp Allergy. 2008 [DOI]10.1111/j.1365-2222.2008.03059.x,
Chandler D et al., Effects of plant‐derived polyphenols on TNF‐α and nitric oxide production induced by advanced glycation endproducts. Mol Nutr Food Res. 2010 [DOI]10.1002/mnfr.200900504,
Fichter M et al., Polymeric hepatitis C virus non-structural protein 5A nanocapsules induce intrahepatic antigen-specific immune responses. Biomaterials. 2016 [DOI]10.1016/j.biomaterials.2016.08.046,
Marzocco S et al., Supplementation of Short-Chain Fatty Acid, Sodium Propionate, in Patients on Maintenance Hemodialysis: Beneficial Effects on Inflammatory Parameters and Gut-Derived Uremic Toxins, A Pilot Study (PLAN Study). J Clin Med. 2018 [DOI]10.3390/jcm7100315,
Lu R et al., Imbalance of autophagy and apoptosis in intestinal epithelium lacking the vitamin D receptor. FASEB J. 2019 Jul [DOI]10.1096/fj.201900727R,
Ponziani FR et al., Influence of hepatitis C virus eradication with direct-acting antivirals on the gut microbiota in patients with cirrhosis. Aliment Pharmacol Ther. 2018 Dec [DOI]10.1111/apt.15004,
Andersen K et al., Intestinal Dysbiosis, Barrier Dysfunction, and Bacterial Translocation Account for CKD-Related Systemic Inflammation. J Am Soc Nephrol. 2017 Jan [DOI]10.1681/ASN.2015111285,
Hicks JM et al., Real-time bacterial detection with an intracellular ROS sensing platform. Biosens Bioelectron. 2019 Sep [DOI]10.1016/j.bios.2019.111430
[注意事項] 【安衛法】この商品は、労働安全衛生法で定める皮膚等障害化学物質等を含みます。

※サムネイル画像をクリックすると拡大画像が表示されます。


プロトコール

メーカー 品番 包装
HCB HIT302 3*96 WELL
希望販売価格 ¥234,000

※表示価格について

当社在庫 なし
納期目安 2週間程度
法規制
保存温度 4℃

 

商品のお問い合わせはこちら

 

メーカー情報
メーカー名 Hycult Biotech (Former Hycultbiotechnology)
略号 HCB
※当社では商品情報の適切な管理に努めておりますが、表示される法規制情報は最新でない可能性があります。
 また法規制情報の表示が無いものは、必ずしも法規制に非該当であることを示すものではありません。
 商品のお届け前に最新の製品法規制情報をお求めの際はこちらへお問い合わせください。  
※当社取り扱いの試薬・機器製品および受託サービス・創薬支援サービス(納品物、解析データ等)は、研究用としてのみ販売しております。
 人や動物の医療用・臨床診断用・食品用としては、使用しないように、十分ご注意ください。
 法規制欄に体外診断用医薬品と記載のものは除きます。
※リンク先での文献等のダウンロードに際しましては、掲載元の規約遵守をお願いします。

© COSMO BIO